<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.eurjchem.com/lib/pkp/xml/oai2.xsl" ?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
		http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-04-19T06:06:15Z</responseDate>
	<request identifier="oai:ojs.www.eurjchem.com:article/1016" metadataPrefix="oai_dc" verb="GetRecord">https://www.eurjchem.com/index.php/eurjchem/oai</request>
	<GetRecord>
		<record>
			<header>
				<identifier>oai:ojs.www.eurjchem.com:article/1016</identifier>
				<datestamp>2014-06-30T08:07:08Z</datestamp>
				<setSpec>eurjchem:ART</setSpec>
				<setSpec>driver</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">M sub-shell X-ray fluorescence cross-section measurements in high Z elements with X-ray tube photon source</dc:title>
	<dc:creator>Gupta, Sheenu</dc:creator>
	<dc:creator>Kaur, Gurpreet</dc:creator>
	<dc:creator>Bansal, Himani</dc:creator>
	<dc:creator>Mittal, Vijay Kumar</dc:creator>
	<dc:creator>Mittal, Raj</dc:creator>
	<dc:subject xml:lang="en-US">M sub-shell X-rays</dc:subject>
	<dc:subject xml:lang="en-US">Selective excitation</dc:subject>
	<dc:subject xml:lang="en-US">Bremsstrahlung X-rays</dc:subject>
	<dc:subject xml:lang="en-US">Variable energy photons</dc:subject>
	<dc:subject xml:lang="en-US">X-ray tube photon source</dc:subject>
	<dc:subject xml:lang="en-US">X-ray fluorescence cross-section</dc:subject>
	<dc:description xml:lang="en-US">X-ray tube has been used for selective M sub-shell excitations in a single reflection set-up for Pt, Au, Pb, Th and U required for M sub-shell fluorescence cross-sections measurements. Weighted photon energy and total intensity of the incident flux between EM5 edge and tube anode voltage were evaluated following a specific procedure. Comparison of measured cross-sections with the calculated ones from existing DHS/DF model based theoretical data on atomic parameters lend support to the present findings.</dc:description>
	<dc:publisher xml:lang="en-US">Atlanta Publishing House LLC</dc:publisher>
	<dc:date>2014-06-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://www.eurjchem.com/index.php/eurjchem/article/view/1016</dc:identifier>
	<dc:identifier>10.5155/eurjchem.5.2.363-369.1016</dc:identifier>
	<dc:source xml:lang="en-US">European Journal of Chemistry; Vol. 5 No. 2 (2014): June 2014; 363-369</dc:source>
	<dc:source>2153-2257</dc:source>
	<dc:source>2153-2249</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://www.eurjchem.com/index.php/eurjchem/article/view/1016/pdf_1016</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
	</GetRecord>
</OAI-PMH>
