<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.eurjchem.com/lib/pkp/xml/oai2.xsl" ?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
		http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-04-16T15:20:35Z</responseDate>
	<request identifier="oai:ojs.www.eurjchem.com:article/1058" metadataPrefix="oai_dc" verb="GetRecord">https://www.eurjchem.com/index.php/eurjchem/oai</request>
	<GetRecord>
		<record>
			<header>
				<identifier>oai:ojs.www.eurjchem.com:article/1058</identifier>
				<datestamp>2014-09-30T03:41:50Z</datestamp>
				<setSpec>eurjchem:ART</setSpec>
				<setSpec>driver</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Development and validation of a new RP-HPLC method for the determination of process related impurities in pioglitazone hydrochloride</dc:title>
	<dc:creator>Prava, Venkata Raj Kumar</dc:creator>
	<dc:creator>Seru, Ganapaty</dc:creator>
	<dc:subject xml:lang="en-US">RP-HPLC</dc:subject>
	<dc:subject xml:lang="en-US">Thiazolidinedione</dc:subject>
	<dc:subject xml:lang="en-US">Method development</dc:subject>
	<dc:subject xml:lang="en-US">Forced degradation study</dc:subject>
	<dc:subject xml:lang="en-US">Process related impurities</dc:subject>
	<dc:subject xml:lang="en-US">Pioglitazone hydrochloride</dc:subject>
	<dc:description xml:lang="en-US">A reversed phase high performance liquid chromatographic method for the determination of process related impurities in pioglitazone hydrochloride was developed and validated. High-quality separation was achieved on a Luna C18 column (150 mm × 4.6 mm, 3 µm) using gradient elution at a flow rate of 1 mL/min and a column temperature of 45 °C. UV detection was performed at 254 nm. The validation was performed according to the International Conference on Harmonization (ICH) guidelines. In addition, the solution stability and method robustness were examined. The method gives satisfactory separation of impurities of pioglitazone hydrochloride and so it is suitable for quantification of the process related impurities as well as for the assay of the active compound.</dc:description>
	<dc:publisher xml:lang="en-US">Atlanta Publishing House LLC</dc:publisher>
	<dc:date>2014-09-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://www.eurjchem.com/index.php/eurjchem/article/view/1058</dc:identifier>
	<dc:identifier>10.5155/eurjchem.5.3.469-474.1058</dc:identifier>
	<dc:source xml:lang="en-US">European Journal of Chemistry; Vol. 5 No. 3 (2014): September 2014; 469-474</dc:source>
	<dc:source>2153-2257</dc:source>
	<dc:source>2153-2249</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://www.eurjchem.com/index.php/eurjchem/article/view/1058/pdf_1058</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
	</GetRecord>
</OAI-PMH>