<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.eurjchem.com/lib/pkp/xml/oai2.xsl" ?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
		http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-04-18T12:18:02Z</responseDate>
	<request identifier="oai:ojs.www.eurjchem.com:article/1433" metadataPrefix="oai_dc" verb="GetRecord">https://www.eurjchem.com/index.php/eurjchem/oai</request>
	<GetRecord>
		<record>
			<header>
				<identifier>oai:ojs.www.eurjchem.com:article/1433</identifier>
				<datestamp>2016-06-30T06:25:29Z</datestamp>
				<setSpec>eurjchem:ART</setSpec>
				<setSpec>driver</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Novel contribution in online sample cleanup for quantitative determination of Levetiracetam in human plasma by LC-Tandem mass spectrometry</dc:title>
	<dc:creator>Mostafa, Ahmed Abdalazim</dc:creator>
	<dc:subject xml:lang="en-US">MRM</dc:subject>
	<dc:subject xml:lang="en-US">Epilepsy</dc:subject>
	<dc:subject xml:lang="en-US">LC-MS/MS</dc:subject>
	<dc:subject xml:lang="en-US">Guard column</dc:subject>
	<dc:subject xml:lang="en-US">Tandem mass</dc:subject>
	<dc:subject xml:lang="en-US">Online sample cleanup</dc:subject>
	<dc:description xml:lang="en-US">The aim of this work was to develop and validate a simple, sensitive and rapid method for the quantitation of levetiracetam (LEV) in plasma using LC-Tandem mass spectrometry. Plasma samples were prepared by simple protein precipitation using acetonitrile; atenolol was used as internal standard (IS). Chromatographic separation was done on Luna 5 µm C18(2) (Phenomenex) 50 × 2.0 mm using gradient flow using solvent A (0.1% formic acid) and solvent B (0.1% formic acid in acetonitrile: water, 95:5, v:v). The positive-ion mass spectrometric detection method utilized electrospray ionization and the multiple reaction monitoring (MRM) mode. The MRM ion transitions were170.9 → 140.8 and 267.3 → 145.1 for levetiracetam and atenolol, respectively. The retention time of levetiracetam and atenolol is 3.24 and 2.96 min, respectively. The total run time was 5 min. The assay was validated over a concentration range from 1 to 100 µg/mL. The method was robust (minimal matrix effect), sensitive (LOQ, 1 µg/mL) metabolites and reproducible (The precision and accuracy for both intra- and inter-day were acceptable &amp;lt;15%). The method can be done on traditional LC-MS equipment. The method was effectively applied to single case study receiving toxic dose of LEV.</dc:description>
	<dc:publisher xml:lang="en-US">Atlanta Publishing House LLC</dc:publisher>
	<dc:date>2016-06-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://www.eurjchem.com/index.php/eurjchem/article/view/1433</dc:identifier>
	<dc:identifier>10.5155/eurjchem.7.2.238-242.1433</dc:identifier>
	<dc:source xml:lang="en-US">European Journal of Chemistry; Vol. 7 No. 2 (2016): June 2016; 238-242</dc:source>
	<dc:source>2153-2257</dc:source>
	<dc:source>2153-2249</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://www.eurjchem.com/index.php/eurjchem/article/view/1433/pdf_1433</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
	</GetRecord>
</OAI-PMH>
