<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.eurjchem.com/lib/pkp/xml/oai2.xsl" ?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
		http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-05-20T04:57:26Z</responseDate>
	<request identifier="oai:ojs.www.eurjchem.com:article/1813" metadataPrefix="oai_dc" verb="GetRecord">https://www.eurjchem.com/index.php/eurjchem/oai</request>
	<GetRecord>
		<record>
			<header>
				<identifier>oai:ojs.www.eurjchem.com:article/1813</identifier>
				<datestamp>2019-06-30T04:04:09Z</datestamp>
				<setSpec>eurjchem:ART</setSpec>
				<setSpec>driver</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Development and validation of stability indicating HPLC method for quantification of tinidazole</dc:title>
	<dc:creator>Ahmed, Randa Bakheet</dc:creator>
	<dc:creator>Abdelaziz, Mohamed El-Muktar</dc:creator>
	<dc:creator>Saeed, Ahmed Elsadig Mohammed</dc:creator>
	<dc:subject xml:lang="en-US">HPLC</dc:subject>
	<dc:subject xml:lang="en-US">Validation</dc:subject>
	<dc:subject xml:lang="en-US">Tinidazole</dc:subject>
	<dc:subject xml:lang="en-US">Factorial design</dc:subject>
	<dc:subject xml:lang="en-US">Stability indicating</dc:subject>
	<dc:subject xml:lang="en-US">Method development</dc:subject>
	<dc:description xml:lang="en-US">A simple, precise, reproducible and economical HPLC method for estimation of tinidazole has been developed. The wavelength of 317 nm is selected as λmax for tinidazole in phosphate buffer (pH = 6.8). Validation parameters were tested following International Conference on Harmonization (ICH) guideline. Tinidazole shows linearity at the selected wavelength and obeys Beer’s law in the concentration range of 3.2-40.0 µg/mL with correlation coefficient of 0.9999. Recovery studies for tinidazole were performed and the percentage recovery was obtained in the range of 99.10-102.45% confirming the accuracy of the proposed method. The method showed good reproducibility and recovery with %RSD less than 2. Statistical validation of the data shows that the proposed method can be used as stability indicating method which successfully applied for the routine analysis of drug in commercial tablets.</dc:description>
	<dc:publisher xml:lang="en-US">Atlanta Publishing House LLC</dc:publisher>
	<dc:date>2019-06-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://www.eurjchem.com/index.php/eurjchem/article/view/1813</dc:identifier>
	<dc:identifier>10.5155/eurjchem.10.2.102-107.1813</dc:identifier>
	<dc:source xml:lang="en-US">European Journal of Chemistry; Vol. 10 No. 2 (2019): June 2019; 102-107</dc:source>
	<dc:source>2153-2257</dc:source>
	<dc:source>2153-2249</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://www.eurjchem.com/index.php/eurjchem/article/view/1813/pdf_1813</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Authors</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
	</GetRecord>
</OAI-PMH>
